ALL PRODUCTS

Return

Magnetron

Price:

Order requiring:

Overview


Frequency range (cooling water 40 )   

2993 to 3002 MHz

Peak output power          

 2.6 MW

Magnet                           

 separate

Output      

 to no.10(WR284) waveguide

 

(72.14 x 34.04 mm internal)

Cooling                    

 water

 

GENERAL DATA

Electrical

Anode Voltage              

 45KV

Anode Current                

 110A

Cathode                   

 indirectly heated

Heater voltage                

 8.5 Vdc

Heater current            

 9.0 A

Peak heater starting current,

 

not to be exceeded        

 20 Amax

Cathode pre-heating time (minimum)     

3.0 min

 

Mechanical

Net weight                   

 8 kg approx

Tuner revolutions to cover frequency range    

4.75

Electromagnet              

 MG6061/MG6062

Waveguide transition            

 M4152S